 Beaches - East York advantage....Two storey garden suites only require 5 meter separation from main dwelling vs. 7.5 elsewhere https://image.nostr.build/893248ccf962accae490da4eae7a98ac16356885c22f2e1bde412da9dd328b53.jpg 
 Fire Department Access Requirements:

Garden Suites

Path of Travel Width & Height: Minimum 1.0m wide by 2.1m high.

Location: Path can be on the property or shared with a neighbor via a Limiting Distance Agreement.

Protrusions Allowed: Hydro, gas meters, and other similar features may project into the path.

Travel Distance: Max 45m from a public street to the suite entry.

Hydrant Proximity: Fire hydrant within 45m of the fire truck's location at the street or flanking street.


Laneway Suites

Path of Travel Width & Height: Minimum 0.9m wide by 2.1m high.

Location: Path can be on the property or shared via a Limiting Distance Agreement.

Protrusions Allowed: Hydro, gas meters, and similar features may project into the path.

Travel Distance: Max 45m from a public street or max 90m through a laneway if additional fire-safety measures are added.

Hydrant Proximity: Fire hydrant within 45m of the fire truck’s location on a public street or flanking street.


 
 
nostr:nevent1qqsq7a57sfz0yg8wuvydh6uc9v0w8kw2wgfvd4p0xpqfwru3h7sxthqpr4mhxue69uhkummnw3ezucnfw33k76twv4ezuum0vd5kzmp0qgsqfjg4mth7uwp307nng3z2em3ep2pxnljczzezg8j7dhf58ha7ejgrqsqqqqqpzj5yvg 
 DC avoidance - pivot back to triplex + GS strategy for Coxwell 
 pre slab gravel and insulation - Gerrard LWS 

https://m.primal.net/LZMX.jpg
https://m.primal.net/LZMY.jpg
 
 Investigating helical piles + slab for Jones GS - first floor height is 6" above grade 
 new first floor above old - lvl ledger board connected to existing masonry wall with 3/4" anchor wedge bolts - Jones

https://m.primal.net/LQbq.jpg
https://m.primal.net/LQbu.jpg
https://m.primal.net/LQbv.jpg
 
 Water line re-run. 2.44m horizontal clearance from sewer line + protective sleeve and tracer wire - Gerrard 

https://m.primal.net/LPBK.jpg
https://m.primal.net/LPBN.jpg
https://m.primal.net/LPBO.jpg
 
 LWS drain and water connection - Gerrard 

https://m.primal.net/KvNL.jpg
https://m.primal.net/KvNM.jpg
 
 125a per unit + 100a house meter

https://m.primal.net/KsAl.jpg
 