Fire Department Access Requirements:
Garden Suites
Path of Travel Width & Height: Minimum 1.0m wide by 2.1m high.
Location: Path can be on the property or shared with a neighbor via a Limiting Distance Agreement.
Protrusions Allowed: Hydro, gas meters, and other similar features may project into the path.
Travel Distance: Max 45m from a public street to the suite entry.
Hydrant Proximity: Fire hydrant within 45m of the fire truck's location at the street or flanking street.
Laneway Suites
Path of Travel Width & Height: Minimum 0.9m wide by 2.1m high.
Location: Path can be on the property or shared via a Limiting Distance Agreement.
Protrusions Allowed: Hydro, gas meters, and similar features may project into the path.
Travel Distance: Max 45m from a public street or max 90m through a laneway if additional fire-safety measures are added.
Hydrant Proximity: Fire hydrant within 45m of the fire truck’s location on a public street or flanking street.