 @d4b81373 @88f809c5 meter fitter probably won't touch that as it would require messing with the cutout. If it's that decrepit they'll code it as dangerous and DNO/DNO contractor will have to come out 
 @438f0a8f @88f809c5 There's no meter fitter involved yet - they won't replace the meters until I get the cutout and backboard sorted. 
 @d4b81373 @438f0a8f ah, fun times... the sparky/supplier/DNO dance. Like awaiting a conjunction of the planets.

That reminds me: it was the DNO fitting a new incomer who wired the meter tails into our isolator.

We did a dodgy thing and actually detached the original incomer and meter from the crumbling backboard, and hung them from the joists. (Pulled the main fuse to fit a temporary CU.) Then fitted the new board and got the DNO to fix the new incomer and old meter to that. 
 @88f809c5 @d4b81373 it's essentially a  requirement that all pubs have deathtrap electrical installations so you can only be improving things...

I'm happy to fool around with most things but would generally steer well clear of the cutout and service cable, particularly if old. There's a lot that can go wrong 
 @438f0a8f @d4b81373 yeah, we had the problem that nobody was keen to touch it as it was given the back board was disintegrating. The incoming cable is super gnarly, DNO guys treated it like it was an archaeological discovery.

Entire place has now been rewired, there was some seriously dodgy old shit for sure.

Went from this to this sorta photos attached. (Will be somewhat neater and all in a cabinet eventually. Got two sub-boxes elsewhere too.)

https://toot.ale.gd/system/media_attachments/files/111/141/842/635/627/152/original/ec0d2ad8e31d1a79.jpg

https://toot.ale.gd/system/media_attachments/files/111/141/843/434/649/329/original/61ae6e96bc33f9b9.jpg 
 @88f809c5 @d4b81373 if it's really bad (including metal cutouts like this festering example of 1920s/30s vintage) they'll dig up the street, isolate and joint it

https://assets.chaos.social/media_attachments/files/111/141/974/261/858/028/original/3adee3879f74fa73.jpg 
 @438f0a8f @88f809c5 @d4b81373 yikes, that looks just a little bit terrifying 
 @5d9036a4 @438f0a8f @d4b81373 I do enjoy the "penalty for breach of this enclosure FIVE POUNDS" 🤣 
 @438f0a8f @d4b81373 ah, now that's a real beauty. I was worried we'd end up with something like that happening, which would have been a total nightmare... but thankfully we escaped that outcome and they judged it OK for the 100A upgrade.